Course outline

SAN Implementation

Categories: Guaranteed To Run™, NetApp

Duration: 3 Days

In this workshop course, you learn how to connect Windows©_, vSphere, and Linux©_ hosts via Fibre Channel (FC) and iSCSI protocols to NetApp©_ SANs.

By the end of this course you should be able to:

  • Define and describe SANs that use FC and iSCSI protocols
  • Configure Windows Server 2008 R2, vSphere 5, Red Hat©_ 5, and Data ONTAP©_ systems for iSCSI connectivity
  • Configure Windows Server 2008 R2, vSphere 5, Red Hat 5, and Data ONTAP systems for FC connectivity
  • Use FC and iSCSI protocols to create and access LUNs from Windows Server 2008 R2, vSphere 5, and Red Hat 5 systems
  • Install and use SnapDrive©_ for Windows and SnapDrive for Linux software to create LUNs and Snapshot LUNs, to restore LUNs from Snapshot copies, and to remove LUNs
  • Size, clone, back up, and recover LUNs on Windows Server 2008 R2, vSphere 5, and Red Hat 5 systems
  • Install and Configure vSphere 5 using the NetApp Virtual Storage Console 4
  • Troubleshoot SAN connectivity and performance issues

below is required before attending this class:

  • Data ONTAP 7-Mode Administration (D7ADM)
  • Accelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87)
  • SAN Fundamentals on Data ONTAP WBT

Professionals who implement SAN solutions that use NetApp storage systems

Module 1 San Review

  • Describe the differences between network-attached storage (NAS) and storage area network (SAN)
  • List the methods to implement SAN solutions
  • Define initiator, target and LUN
  • Describe ports, worldwide names, and worldwide port names
  • List the steps to implement a SAN

Module 2 Windows FC Connectivity

  • Describe multiple path implementation with Fiber Channel (FC) connectivity
  • Configure FC ports on Windows©_and NetApp©_FAS systems
  • Use commands and utilities to identify the worldwide node name (WWNN) and worldwide port name (WWPN) on Windows and NetApp systems
  • Use commands and utilities to examine FC switch activity

Module 3 Windows iSCSI Connectivity

  • Describe multiple path implementation with iSCSI connectivity
  • Configure network ports on Windows©_and NetApp©_systems
  • Identify the node name on Windows and NetApp systems
  • Implement and verify multiple path iSCSI connectivity between Windows and NetApp systems

Module 4 Windows LUN Access

  • Discuss LUN Access for Windows Server 2008 R2
  • Create a LUN using wizards
  • Explore techniques to configure a LUN for Windows Server 2008 R2
  • Explain how SnapDrive for Windows simplifies LUN management

Module 5 vSphere Overview

  • Describe virtualization and how it can be used to promote server efficiency
  • Explain methods of mapping NetApp©_storage to Vmware vSphere datastores
  • List the interfaces to administrate vSphere

Module 6 vSphere FC Connectivity

  • Describe multiple path implementation with Fibre Channel (FC) connectivity for VMware vSphere and NetApp©_systems
  • Configure FC ports on vSphere systems
  • Identify the worldwide node name (WWNN) and worldwide port name (WWPN) on vSphere systems
  • Configure and verify multiple path FC connectivity between vSphere and NetApp systems

Module 7 vSphere iSCSI Connectivity

  • Describe multiple path implementation with iSCSI connectivity for vSphere and NetApp©_systems
  • Configure network ports on vSphere systems
  • Identify the node name on vSphere systems
  • Configure and verify multiple path iSCSI connectivity between vSphere and NetApp systems

Module 8 vSphere LUN Access

  • Describe the steps that you take to allow a VMware vSphere initiator to access a LUN on a storage system as a Virtual Machine File System (VMFS) datastore
  • Describe the steps that you take to allow a vSphere initiator to create a virtual machine (VM) with a raw device mapping (RDM) disk from a storage system’s LUN

Module 9 NetApp Storage and Red Hat

  • Describe Red Hat©_Enterprise Linux©_
  • Explain why NetApp©_storage is ideal for LUNs that are managed by Red Hat Enterprise Linux

Module 10 Red Hat FC Connectivity

  • Describe multiple path implementation with Fiber Channel (FC) connectivity for Red Hat©_and NetApp©_systems
  • Configure FC ports on Red Hat systems
  • Identify the worldwide node name (WWNN) and worldwide port name (WWPN) on Red Hat systems
  • Set up and verify multiple path FC connectivity between Red Hat and NetApp systems

Module 11 Red Hat iSCSI Connectivity

  • Describe multiple path implementation with iSCSI connectivity for Red Hat©_and NetApp©_systems
  • Configure network ports on Red Hat systems
  • Identify the node name on Red Hat systems
  • Set up and verify multiple path IP connectivity between Red Hat and NetApp systems

Module 12 Red Hat LUN Access

  • Describe the steps to allow a Red Hat©_initiator to access a LUN on a storage system

Module 13 LUN Provisioning

  • Describe how and when a LUN consumes space from its containing volume
  • Discuss backup guarantees through NetApp Snapshot reserve
  • Discuss the overwrite guarantee for space-reserved LUNs
  • Analyze the default LUN configuration and two thin-provisioning configurations

Module 14 SAN Management

  • Perform administrative tasks on FC target ports
  • Perform administrative tasks on LUNs
  • Perform administrative tasks on initiator groups ( igroups)

Module 15 SAN Troubleshooting

  • Explain how to diagnose a problem within a SAN environment
  • Lab 1-1 Identify the hardware that is available in your exercise environment
  • Lab 1-2 Log into the exercise environment
  • Lab 1-3 Identify whether a configuration is supported by the interoperability matrix
  • Lab 2-1 Investigate the initial switch configuration
  • Lab 2-2 Configure FC HBAs on a storage system pair
  • Lab 2-3 Configure HA on your storage system pair
  • Lab 2-4 Configure FC HBAs on each storage controller
  • Lab 2-5 Configure Windows for multipath I/O
  • Lab 2-6 Install NetApp DSM for Windows
  • Lab 2-7 Install the Windows Host Utilities
  • Lab 2-8 Enable FC HBAs ports on Windows 2008 system
  • Lab 2-9 Assign aliases to WWPNs on your storage system
  • Lab 3-1 Configure iSCSI on storage system
  • Lab 3-2 Configure an iSCSI session on a Windows machine
  • Lab 3-3 Confirm the iSCSI session on storage system
  • Lab 3-4 Configure a second iSCSI on a Windows machine
  • Lab 3-5 Confirm the second iSCSI session on storage system
  • Lab 4-1 Create a FC LUN (FCP) with the LUN SETUP command
  • Lab 4-2 Use disk management to initialize a FC LUN 
  • Lab 4-3 Use disk management to provision a FC LUN
  • Lab 4-4 Use separate commands to create an iSCSI LUN
  • Lab 4-5 Use the CLI to initialize and provision an iSCSI LUN
  • Lab 4-6 Make the mounting of an iSCSI LUN persistent
  • Lab 4-7 Set up accounts for SnapDrive 6.4 for Windows
  • Lab 4-8 Install SnapDrive 6.4 for Windows
  • Lab 4-9 Use SnapDrive for Windows to create a LUN
  • Lab 4-10 Use SnapDrive for Windows to create a Snapshot copy and restore from the Snapshot copy
  • Lab 4-11 Configure multiple paths with MPIO
  • Lab 4-12 Working with Dynamic Disks
  • Lab 5-1 Remove Windows LUNS, igroups and volumes
  • Lab 5-2 Login to the vSphere client and explore the default configuration
  • Lab 5-3 Install NetApp virtual storage console
  • Lab 5-4 Log in to the vCenter and configure a datastore
  • Lab 5-5 Explore the virtual storage console
  • Lab 6-1 Configure FC services on storage system
  • Lab 6-2 Configure FC HBAs on ESXI
  • Lab 6-3 Aliasing WWPNs
  • Lab 7-1 Configure iSCSI on Storage System
  • Lab 7-2 Configure the virtual IP infrastructure on ESXI
  • Lab 7-3 Configure iSCSI on ESXI
  • Lab 7-4 Confirm iSCSI sessions on the storage system
  • Lab 8-1 Install NetApp System Manager
  • Lab 8-2 Create a FC LUN for a VMFS datastore using NetApp System Manager
  • Lab 8-3 Create a VMFS datastore
  • Lab 8-4 Create a VM within a VMFS datastore
  • Lab 8-5 Create a VMFS datastore using virtual storage console
  • Lab 8-6 Create a VM within a VMFS datastore
  • Lab 8-7 Create a FC LUN for an RDM datastore using OnCommand System Manager
  • Lab 8-8 Create a VM with a RDM datastore
  • Lab 8-9 Create an iSCSI LUN for an RDM datastore using OnCommand System Manager
  • Lab 8-10 Create a VM with a RDM datastore 
  • Lab 9-1 Remove ESX LUNs, igroup and volumes
  • Lab 10-1 Verify your Linux configuration
  • Lab 10-2 Install Qlogic SANsurfer for your Linux system
  • Lab 10-3 Install the NetApp Linux Host Utilities on your Linux System
  • Lab 10-4 Investigate initial FC Switch configuration and create zoning
  • Lab 10-5 Verify high availability and FC configuration on a high availability storage system
  • Lab 10-6 Verify FC connectivity
  • Lab 10-7 Provide alias for WWPNs
  • Lab 11-1 Configure the iSCSI software initiator on Linux 
  • Lab 11-2 Confirm the iSCSI sessions on the storage system
  • Lab 12-1 Create an FC-attached LUN for Linux
  • Lab 12-2 Discover an FC-attached LUN from Linux
  • Lab 12-3 Enable Linux native multipathing
  • Lab 12-4 Create iSCSI-attached LUNs for Linux
  • Lab 12-5 Discover iSCSI-attached LUNs from Linux
  • Lab 12-6 Prepare an individual LUN and mount it on Linux
  • Lab 12-7 Configure an LVM2 logical volume
  • Lab 13-1 Create an iSCSI-attached LUN on a NetApp high availability storage system
  • Lab 13-2 Configure an iSCSI-attached LUN on Linux
  • Lab 13-3 Create a Snapshot copy of a LUN
  • Lab 13-4 Observe the effects of writing to a LUN
  • Lab 13-5 Observe the effects of deleting from a LUN
  • Lab 13-6 Observe the effects of overwriting to a LUN
  • Lab 13-7 Observe the effects of setting Snapshot automatic deletion policy
  • Lab 14-1 Clone a LUN for Linux
  • Lab 14-2 Remove a LUN with Linux

Feel free to contact us, if you want to know the price and location of this course. A Digital Revolver representative will contact you shortly to help you with your inquiry.
Please fill out the form below

  • Guaranteed to Run™. This ensures you will attend the instructor led class or live online class you want as scheduled without any disruptive cancellations*. You book the training you need, get back to focusing on your job and are sure your training requirements will be met saving time, money and ensuring peace of mind.
  • This schedule icon the schedule indicates that this date/time will be conducted as Instructor Led Training (ILT) or a Virtual Instructor Led Training (VILT) depending on the indicated class availablity.
Privacy and Cookies

This website stores cookies on your computer which help us make the website work better for you.

Learn moreAccept and Close